Riester ri-champion® smartPRO+
MODEL
1735-BT
HSN CODE
90189019
EAN UPC CODE
EAN - NA
Close
Close
Brand:
Rudolf Riester GmbH
Category:
Blood Pressure Measurement
>
Digital Blood Pressure Monitors
DETAILS
ri-champion® smartPRO+ Non-invasive, blood pressure Monitor
The Riester ri-champion® smartPRO+ Clinically validated blood pressure monitor, designed for fast and reliable readings. Advanced performance by indicating irregular heartbeat detection and average measurement function.
A clinically validated blood pressure monitor, designed for fast and reliable readings. Advanced performance with irregular heartbeat detection and averaging capabilities.
The Riester ri-champion® smartPRO+ is a portable, clinically validated Blood Pressure Monitor, with irregular heartbeat detection and the simplicity needed for reliable blood pressure readings.
Clinical Validation
› Meets EN1060-4, NIBP clinical investigation
› CE/FDA Approved
› Accuracy to ±3 mmHg or ±2% of reading
Automatic Diagnostics
› Irregular heartbeat detection
› Averaging measurement function
› Optional Bluetooth® connectivity
Patient Friendly
› Fast & quiet operation
› 200 measurements on one set of 4 AA batteries
› Large, easy to read backlit screen
SPECS
Height -
Weight -
Breadth -
Length -
Energy Saving - Automatic power off if system idle for 3 minutes
Accuracy - Accuracy of Pressure: ±3 mmHg or ±2% of reading, Accuracy of Pulse rate: ±4% of reading
Power source - Four 1.5 V AA alkaline batteries / DC + 6 V / 1 A (max) via Power Plug
Cuff Specifications - S (Small): 19 - 25 cm (7.5 - 9.8 inches) with air tube 80 cm W (Wide size): 24 - 43 cm (9.4 - 16.9 inches) with air tube 80 cm
Data Storage - Maximum 400 memory rec
Measuring range - Heart Rate Range: 40 – 199 beat per minute, Systolic Measurement Range: 60 mmHg - 255 mmHg, Diastolic Measurement Range: 30 mmHg - 195 mmHg, Pulse Rate Measurement Range: 40 - 199 beats / minute
Display Unit - Either mmHg or kPa
Data Transfer - Bluetooth (ri-champion® smartPRO+ only) (Frequency: 2.45 GHz, Bandwidth: 170 MHz, Modulation: GFSK, ERP: 3.54 dBm)
Irregular heartbeat detection - Yes
Power Consumption - 200 Readings
Operating Conditions: - 5°C to 40°C (41°F to 104°F), 15 % to 93 % relative humidity, 700 hPa to 1060 hPa null
Storage / Transportation Conditions: - -25°C to 70°C (-13°F to 158°F), 10 % to 95 % relative humidity null
Maximum Inflation Pressure - 280 mmHg null
ENQUIRY FORM
Send Enquiry to Manufacturer
Enquire about the price, product information and specification. Enquiry will be sent to Manufacturer and their authorized dealers only.
Full Name
Email Address
Phone Number
Query
Success! Enquiry has been submitted and you will receive further updates over email.
Oops! Something went wrong. Please try again later.
Create Enquiry
Buy Direct
Enquire directly with Rudolf Riester GmbH and their authorized dealers on the platform
Related products
{{name}}
{{companyName}}