Resmed AirCurve™ 10 VAuto

MODEL

37481

HSN CODE

90192090

EAN UPC CODE

NA

Brand: ResMed
Category: Device > Sleep
 
Resmed AirCurve 10 V Auto

The AirCurve 10 VAuto is an auto-adjusting bilevel machine that uses the comfort of both the AutoSet™ algorithm and Easy-Breathe waveform in its  VAuto algorithm to treat obstructive sleep apnea patients who can benefit from greater pressure support. The AirCurve 10 VAuto adjusts the baseline pressure to hold the airway open while maintaining a fixed pressure support.

Easy-Breathe technology

The Easy-Breathe pressure waveform mimics the wave shape of normal breathing and replicates it for your breathing comfort.

Climate Control
                   
Every device comes with the new HumidAir™ heated humidifier built-in, so you can enjoy the benefits of humidification in one easy-to-use system. And when used with the ClimateLineAir™ heated tube, your device has been designed to automatically deliver the optimal temperature and humidity, for a more comfortable therapy experience.

Other features 

  • Continuous leak management enables reliable delivery of therapy pressure while maintaining patient-device synchrony.
  • Compatible with up to 15 L/min of supplemental oxygen in S and CPAP mode and 4 L/min in VAuto mode.
  • Consistent humidification throughout the night with the integrated HumidAir™ humidifier and optional ClimateLineAir™ heated tube with Climate Control technology can provide a more comfortable experience.
  • The quiet Easy-Breathe motor makes for a peaceful environment for you and your bed partner.
  • The built-in ambient light sensor adjusts to the brightness of the room. So if you need to get up during the night, the screen’s back light won’t disrupt your bed partner. The light also turns off automatically, so you can settle back to sleep without disturbance.
  • Height - 116 mm
  • Weight - 1248 gm
  • Breadth - 150 mm
  • Length - 255 mm
  • Sound pressure level -
  • Supplemental oxygen Maximum flow - 15 L/min (CPAP, S); 4 L/min (VAuto)
  • Storage and transport humidity - 5 to 95%relative humidity, non-condensing
  • Ramp Time - You can set your Ramp Time to Off or between 5 to 45 minutes.
  • Water capacity: - To maximum fill line 380 mL
  • Air outlet - 22 mm
  • Typical power consumption - 53W (57VA)
  • Sensors - Pressure sensor: Internally located at device outlet, analoguegauge pressure type, -5 to +45cmH2O (-5 to +45 hPa); Flow sensor:Internally located at device inlet, digital mass flow type, -70 to +180 L/min
  • Operating altitude - Sea level to 2,591m; air pressure range 1013hPa to 738 hPa
  • Maximum single fault steady state pressure - Device will shut down in the presence of a single fault if the steady state pressure exceeds:30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
  • Modes - S, VAuto, CPAP
  • Sound power level - Pressure level measured according to EN ISO 17510-1:2009 (CPAP mode):SlimLine:26.6 dBA with uncertainty of 2 dBAStandard:26.6 dBA with uncertainty of 2 dBAPower level measured according to EN ISO 17510-1:2009 (CPAP mode):SlimLine:34.6 dBA with uncertainty of 2 dBAStandard:34.6 dBA with uncertainty of 2 dBADeclared dual-number noise emission values in accordance with ISO4871:1996.
  • Peak power consumption - 104W (108VA)
  • Operating pressure range - S, VAuto: 2 to 25cm H2O (2 to 25 hPa); CPAP: 4 to 20cmH2O (4 to 20 hPa)
  • Power supply unit - 90W power supply unit; AC input range:100–240V, 50–60Hz 1.0–1.5A, Class II115V, 400Hz 1.5A, Class II (nominal for aircraft use); DC output:24V 3.75A
  • Storage and transport temperature - -20°C to +60°C
  • Operating humidity - 10 to 95% relative humidity, non-condensin
  • Housing construction - Flame retardant engineering thermoplastic
  • Operating temperature - +5°C to +35°C Note: The air flow for breathing produced by this therapy device can be higher than the temperature of the room. Under extreme ambient temperature conditions (40°C) the device remains safe.
  • Wireless Module - Technology used:4G, 2G. It is recommended that the device is a minimum distance of 2 cm from the body during operation. Not applicable to masks, tubes or accessories. Technology may not be available in all regions null

Send Enquiry to Manufacturer

Enquire about the price, product information and specification. Enquiry will be sent to Manufacturer and their authorized dealers only.

Create Enquiry Buy Direct
Enquire directly with ResMed and their authorized dealers on the platform