CERAMOTHERM3000 Radiant Warmer

MODEL

WY3100

HSN CODE

90318038

EAN UPC CODE

NA

Brand: Weyer GmbH
Category:
 
Radiant Warmers CERAMOTHERM are the result of nearly 40 years of continuous development in the medical use of infrared radiation. Convenient handling and function, comfortable operation as well as a safe use are the priorities of this radiant warmer.

Impressive warming efficiency

Infrared rays do not warm-up the ambient air but are absorbed by the bodies they impinge on and are so converted into heat. By the new developed high-performance reflector the heat is directed to the patient pad even more efficiently and evenly. The Quick-Heat function produces the required warming energy within shortest time and outshines conventional radiant heaters.

Easy to operate

Same as the well-proven product series THERMOCARE and VARIOTHERM, intensity and light are selected intuitively according to the principle “Select - Adjust - Confirm”.

So an unintentional direct adjustment, e.g. by visitors, is prevented.

At different light conditions (day, night) the brightness of the colour display is automatically adapted to the ambience, so the display can be read-off clearly at any time. When the device has cooled down after switch-off, the display is darkened, so the night’s sleep is not disturbed.

Intensity adjustment as required

Rough settings of heating capacity in steps are a thing of the past. In particular for small infants a sensitive adjustment of the radiation intensity according to their demand is a must.

The CERAMOTHERM system allows a fine adjustment of the intensity in mW/cm², optionally in %.

The selected intensity emitted to the patient is calculated by a processor according to the distance to the patient pad. It is controlled precisely and indicated in the actual intensity display.

This technique allows maintaining the body temperature in adults, infants and even smallest preterm babies during intensive care.

Homogeneous illumination

For the smallest patients the best light is just good enough. Infants, in particular new born babies, are stressed when they are dazzled by a sudden glaring spot-light.

Therefore the large-area lamps of the CERAMOTHERM 3000 switch on and off the light gently. Small patients remain calm and feel cosy.

The colour temperature of the light is 4000 Kelvin which guaranties an excellent appearance and is suitable for examination and minor operations. The illumination intensity can be adapted in 5 steps according to the actual situation. So the optimum light is always available.

Integrated timers

With the 3 integrated timers the radiant warmer CERAMOTHERM is a device for versatile use.

• Apgar-Timer. For postnatal care of new born babies.

• Stop watch. Helpful in many applications.

• Countdown-timer: Always indispensable for applications with limited time frame (in the action range of the radiant warmer).

Integrated safety

For cost reasons many radiant warmers in the market do not provide essential safety features. A part of their exposed surfaces can become dangerously hot because they do not have efficient protection, switch-off and warning devices.

Not so the radiant warmers CERAMOTHERM 3000! They have been designed under consideration of the current standards and according to the principle of integrated safety in order to minimize all possible risks by facile but effective technique. So the heating elements are arranged safely behind a finger-touch protection and prevent active children, operators and other persons from touching the 200 - 600 °C hot heating element. The heating elements are shatter-proof so no risk can arise from them.

Furthermore, the risk of hazard for the operator by sharp edges and corners are minimized by the rounded design. So the operator is protected from injuries.

Application with maximum safety

The infrared spectrum of the radiant warmers CERAMOTHERM was chosen in a way that on one hand the patients are warmed efficiently and on the other hand it cannot cause any injuries to the eye and the skin, expert use provided.

Very small or hypothermic patients often require high radiation intensity to maintain their body temperature. In most cases this is above 10 mW/cm² which in the long run can cause hyperthermia and skin injuries. In order to avoid such hazards after a certain time the radiation intensity is automatically reduced to a safe value and a signal sounds to inform the operator. So cooling is avoided and the patient is prevented from hypothermia. The actual intensity and balance time to automatic intensity reduction are displayed.

As the heating elements can remain hot sometime after switching off, the residual intensity is displayed until cooling off.

Autodetect function for height-adjustable radiant warmers, constant intensity for the patient

Radiant warmers CERAMOTERM with height-adjustable wall or ceiling fixtures have an automatic distance detection with patented intensity compensation Autodetect. For other applications this function is available as option.

The Autodetect function will immediately reduce the radiation intensity when the distance to the patient is reduced and it will automatically increase the intensity within shortest time when the distance to the patient is enlarged. The parameters for intensity and distance are displayed accordingly. This is a unique technique which is second to none.

The reflector

Parabolic preflector with formation of a focus.

Radiant warmers CERAMOTHERM have a high-performance reflector that directs the radiation intensity of the heating element directly and evenly to the patient pad. Formation of a hazardous focus is excluded.

Parabolic reflectors with a focus below the radiant warmer are a hazard for the operator and a thing of the past.

  • Height - 100 mm
  • Weight - 4.8 kg
  • Breadth - 450 mm
  • Length - 220 mm
  • Operating voltage / power supply - 230 V – 50/60 Hz null
  • Max. power input - 690 W / 3 A null
  • Heating element(s) - ceramic, life >10 years 1 x 600 W null
  • Wave length spectrum - 1.5 to 6.8 μm null
  • Illumination - on both sides null
  • Dimmable - In 5 Steps null
  • Capacity - 2 X 5.5 W null
  • Illumination intensity (max.) - 2 x 850 lm null
  • Colour temperature - 4000K null
  • Intensity selection display - Yes null
  • Protection class - 1 null
  • MDD-class - IIa null
  • Standards - EN 60601-1: 2006 EN 60601-1-2:2007 EN 60601-2-21:2009* *Particular requirements for basic safety of infant radiant warmers null

Send Enquiry to Manufacturer

Enquire about the price, product information and specification. Enquiry will be sent to Manufacturer and their authorized dealers only.

Create Enquiry
Enquire directly with Weyer GmbH and their authorized dealers on the platform